SUPRAMATIC E SERIE 3 ANLEITUNG
Is the door working ok on manual without the operator connected? The courtesy light should flash and the door should now move into the open position and then continue to move into the closed and open position a number of times to automatically set the doors open and closed limits. Is there a sensor or something that could be going bad that we can replace? The door will fully open and come to a stop. Additional control units and exposed, movable connecting leads are not necessary. Security is one of the main issues concerning remote control garage door openers and Hormann have the answer in their patented locking mechanism. The remote not working is sending out a signal but appears to be unable to control the motor, is there a way I can re-establish the link? We use cookies to provide you with a better website experience.
These will recognise up to nearly individual fingerprints for the ultimate in external security access control at very affordable prices. Turn off the main power supply to the operator at the plug socket. The light is on, on both photocells 2 wires to each showing they have power. Also have you tried resetting the operator after the photocells are installed as follows… 1. Alternatively, it could be an issue with the heat effecting circuits in the control unit. Only during very warm weather, it throws out an error message 4. Learn how your comment data is processed.
I have the P2 motor here in Norway with a set of photocells attached. This guarantees reliable function — at an attractive price. Could be a system fault, but I feel small progress has been made!
Hormann SupraMatic E BiSecur Series 3 garage door opener with M Rails
Hello Mak, There should be an error code on the display screen on the operator, the error code may also display when you press the button to move the garage door up or down. The Series 1 had the PRG button underneath the display and it had a single digit display as opposed to a double digit display.
On load, the door moves only a few inches on opening and stops. Hello David, the garage door should finish the procedure in the open position, so it sounds like the procedure completed successfully. When I run Learn mode, the door cycle is interrupted numerous times up and down, so I have to keep pushing up or down to finish it. Error 4 can sometimes indicate an internal board failure so it is possible that the unit is faulty but often resetting the limits can correct the issue.
Also have you tried resetting the operator after the photocells are installed as follows….
Hormann Electric Garage Doors
This device is in addition to the motor holding the door closed providing one of the most secure operators on the market. Off seerie, Ie with the door disconnected it works fine, and reset was successful. Thanks for your help.
Hello, Do you have any thoughts regarding a problem with my Surpramatic E. When the signal is interrupted another light is seen but the door will not stop and reverse. It would be worth disconnecting the operator and opening and closing the door manually a few times to check supraamtic it is working ok without the operator.
If it is and the hand transmitter is not operating the door it is likely that it has failed. You can see these on our spares site at the link below. Hello Mick, Fault Error 5 indicates there is an error with the garage door and not the motor.
Phil Hall on September 7, The display should now show a single red line at the top of the display to indicate it is in the open position. You will find this combination of speed and convenience unbeatable. If there is no visible sign of any obstructions, we would recommend calling out a professional garage door engineer to investigate further.
Only during very warm weather, anletung throws out an error message 4. View more Hormann how to guides. Is there a sensor or something that could be going bad that we can replace?

The Operator is now fully reset. Supermatic A with the gray remote buttons. The only other option from the prg menuother than i can get is U which is to do with the remote I think. If there is too much resistance it can cause issues with the learning cycles. How do I sync the existing remote or even get back to the stage where pushing the up or down arrow once will automatically open or close the door? Press and release the red LED button. Security is one of the main issues concerning remote control garage door openers and Hormann have the answer in their patented locking mechanism.
The Hormann sectional garage door possibly offers the highest level of security when combined with a suitable Hormann remote control electric operator unit. Without a wiring diagram I assume 1 jack is for photocell jumper and the other is for emergency stop such as door in door contact.
March 19, Author: If it is an issue with the electronics, then the control unit would need to be changed. After this I got a U on the display Any ideas on how to resolve greatly appreciated Thanks. With the dot flashing.
Two transmitters, full installation instructions and 5 year guarantee are included. There should be a series of dip switches inside the hand transmitter and they should zerie the working hand transmitter. Also have you tried resetting the operator after the photocells are installed as follows… 1. This site uses Akismet to reduce spam.